Synchronization of Power Grid by HVDC Technology
DOI:
https://doi.org/10.51983/ajes-2018.7.1.2053Keywords:
Synchronization, HVAC–3HVDC, HVAC–2HVDC parallel tie-line, HVAC–1HVDC parallel tie-line, HVAC–High Voltage Alternating Current, HVDC–High Voltage Direct Current, Traditional integral controllerAbstract
This research work expose the advantages of HVDC technology for synchronization of two interconnected thermal power grid of 12 areas when load disturbance occur in power grid-1. Three types of tie-lines HVAC–1HVDC parallel tie-line, HVAC– 2HVDC parallel tie-line and HVAC–3HVDC parallel tie-line are applied for synchronization of 12 area two interconnected thermal power grid. For synchronization purpose of power grid this research work shows the HVAC–3HVDC parallel tie-line is better as compare to the HVAC–2HVDC parallel tie-line and HVAC–1HVDC parallel tie-lie. This research work also shows the HVAC–2HVDC parallel tie-line is better as compare to the HVAC–1HVDC parallel tie-line. Quality of all three types of tie-line is judged by the frequency deviation of two interconnected power grid of 12 areas when load disturbance occur in power grid-1. The biggest advantage of this research work is that the two interconnected thermal power grid of 12 areas is Synchronize by HVDC technology with traditional integral controller.
References
K. Y. Lim, Y. Wang, and R. Zhou, "Decentralized robust load-frequency control in coordination with frequency-controllable HVDC links," Electric Power Energy System, vol. 19, no. 7, pp. 423–431, 1997.
P. Kumar and Ibraheem, "Dynamics performance evaluation of 2-area interconnected power system: a comparative study," J. Ins. of Engg. (India), Elect. Engg. Division, vol. 78, pp. 199–209, 1998.
I. Ngamroo, "A stabilization of frequency oscillations in a parallel AC – DC interconnected power systems via an HVDC link," Science Asia, vol. 28, pp. 173-180, 2002.
D. P. Kothari and I. J. Nagrath, "Modern Power System Analysis," 3rd ed. Tata McGraw Hill, 2003.
X. P. Zhang, "Multi terminal Voltage Sourced Converter Based HVDC Models for Power Flow Analysis," IEEE Transactions on Power Systems, vol. 18, no. 4, pp. 1877-1884, 2004.
A. Ibraheem, P. Kumar, and D. P. Kothari, "Recent Philosophies of Automatic Generation Control Strategies in Power Systems," IEEE Transactions on Power Systems, vol. 20, no.1, pp. 340-357, Feb. 2005.
H. D. Mathur and H. V. Manjunath, "Study of dynamics of thermal units with asynchronous tie-line using fuzzy based controller," Journal of Electrical Systems, vol. 3, no. 3, pp. 124–130, 2007.
L. Kong and L. Xiao, "A New Model Predictive Control Scheme Based Load Frequency Control," in Proceedings of IEEE International Conference on Control and Automation, pp. 2514–2518, Jun. 2007.
S. Ganapathy and S. Velusami, "Dynamics of MOEA based decentralized load frequency controllers for interconnected power system with AC-DC parallel tie-line," International Journal of Recent Trends in Engineering, vol. 2, no. 2, pp. 357–361, 2009.
C. S. Rao, S. S. Nagaraju, and P. Raju, "Improvement of dynamics performance of AGC under open market scenario employing TCPS and AC-DC parallel tie-line," International Journal of Recent Trends in Engineering, vol. 1, no. 1, 2009.
K. P. S. Parmar, S. Majhi, and D. P. Kothari, "Automatic Generation Control of an Interconnected Hydrothermal Power System," in IEEE Conf. proceedings, INDICON 2010, Kolkata, India.
S. K. Sinha, "Automatic generation control in regulated and restructured power system," Ph.D. dissertation, IIT-R, India, 2010.
Z. Du, Y. Zhang, Z. Chen, P. Li, Y. Ni, and L. Shi, "Integrated emergency frequency control method for interconnected AC-DC power systems using centre of inertia signals," IET Generation, Transmission & Distribution, vol. 6, no. 6, pp. 584-592, 2012.
S. Debbarma, L. C. Saikia, and N. Sinba, "AGC of a multi-area thermal system under deregulated environment using a non-integer controller," Electric Power System Research, pp. 175–183, 2013.
S. Panda and N. K. Yegireddy, "Automatic generation control of multi area power system using multi objective non-dominated sorting genetic algorithm-II," International Journal of Electrical Power System, pp. 54-63, 2013.
K. P. S. Parmar, "State space based load frequency control of multi-area power system," PhD. Thesis, IIT Guwahati, India, Oct. 2013.
MATLAB, "MATLAB Software-Math Works, Inc.," vol. Version 8.1.0.604 (R2013a), Control Toolbox.
P. K. Sahu, "Performance analysis of different tie-line for synchronization of 12-area two interconnected thermal power grid," Asian Journal of Electrical Sciences, vol. 6, no. 2, pp. 37-50, 2017.
P. K. Sahu, "Performance analysis of combined application of FACTS and HVDC parallel tie-line for interconnection and synchronization of large thermal power grid," Journal of Power Electronics & Power Systems, vol. 7, no. 3, pp. 1-16, 2017.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2018 The Research Publication
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.