Investigation of Power Quality Disturbances in an Electric Arc Furnace

Authors

  • K. U. Vinayaka Assistant Professor, Dept. of Electrical and Electronics Engineering, Siddaganga Institute of Technology, Tumakuru, India
  • P. S. Puttaswamy Professor and Head, Dept. of Electrical and Electronics Engineering, PES College of Engineering, Mandya, India

DOI:

https://doi.org/10.51983/ajes-2018.7.1.2062

Keywords:

Electric Arc Furnace(EAF), Power Quality, Voltage Flicker

Abstract

Stochastic performance of an electric arc furnace (EAF) has drawn researcher’s attention due to power quality problems introduced by EAF operation. In this paper, Electric arc furnace is modeled to investigate power quality problems. Voltage flicker, harmonics and inter-harmonics are the main power quality disturbances that arise in the electrical network as a result of arc furnace operation due to the non-linear nature of EAF. A time domain model is derived to study the behavior in various operating conditions (melting and refining). The characteristic modeling of an EAF is carried out in MATLAB (Simulink).

References

S. R. Mendis, M. T. Bishop, and J. F. Witte, "Investigation of voltage flicker in electric arc furnace power system," IEEE, 1994.

G. C. Montanari, M. Loggini, A. Cavallini, and L. Pitti, "Flicker and distortion compensation in electrical plants supplying arc furnace," IEEE, 1994.

G. C. Montanari, M. Loggini, and A. Cavallini, "Arc Furnace Model for the Study of Flicker Compensation in Electrical Networks," IEEE Trans. on Power Delivery, vol. 9, no. 4, pp. 2026-2033, October 1994.

T. Zheng, E. B. Makram, and A. Girgis, "Effect of Different Arc Furnace Model on Voltage Distortion," in IEEE Conference on Harmonics and Quality of Power, pp. 1079-1085, 14-18 Oct. 1998.

T. Zheng and E. B. Makram, "An Adaptive Arc Furnace Model," IEEE Transactions on Power Delivery, vol. 15, no. 3, pp. 931-939, 2000.

L. F. Beites, J. G. Mayordomo, A. Hernandes, and R. Asensi, "Harmonics, Interharmonic, and Unbalances of Arc Furnaces: A New Frequency Domain Approach," IEEE Transactions on Power Delivery, vol. 16, no. 4, pp. 661-668, 2001.

Omer Ozgun and Ali Abur, "Flicker Study Using A Novel Arc Furnace Model," IEEE Transactions on Power Delivery, vol. 17, no. 4, 2002.

A. M. O. Haruni, K. M. Muttaqi, and M. Negnevitsky, "Analysis of harmonics and voltage fluctuation using different models of arc furnace," in 2007 Australasian Universities Power Engineering Conference, pp. 03–08, 2007.

S. H. Cho, J. A. Jung, G. Jang, S. H. Kwon, and M. H. Kang, "Development of Matlab/Simulink Module for Voltage Flicker Simulation in Distribution Power Systems," Journal of Electrical Engineering & Technology, vol. 3, no. 3, pp. 314-319, 2008.

Mahdi Banejad, Rahmat-Allah Hooshmand, and Mahdi Torabian Esfahani, "Exponential-Hyperbolic Model for Actual Operating Conditions of Three-Phase Arc Furnaces," American Journal of Applied Sciences, vol. 6, pp. 1539-1547, 2009.